Thermage in Korea: Results, Hollow Cheeks & 3 Areas I Assess

Thermage in Korea: results, hollow cheeks, and the three areas Dr. Youro assesses before treatment

Want a firmer jawline—but worried Thermage could make your cheeks look hollow?

That concern makes sense when the tissue beside your mouth looks heavy, yet the area below your cheekbone already looks sunken. Treating both areas in the same way misses the point.

Before choosing the number of shots, I identify what is sagging—and what volume needs to stay.

I’m Dr. Youro, a physician practicing in South Korea. Here is how I assess three facial areas before Thermage, why my treatment map changes from face to face, and what published RF before-and-after photos can actually tell you.

Quick answer: Thermage uses radiofrequency heat to improve skin firmness and wrinkles. It does not replace lost facial volume. My priority is to distinguish loose tissue from existing hollows, then adapt treatment to that anatomy.

Jump to: How it works · My three-area assessment · Treatment tips · Device comparison · Clinical photos · FAQ

1. What does Thermage actually do?

Thermage FLX is a 6.78 MHz monopolar radiofrequency (RF) treatment. Electrical energy produces heat within tissue while the surface is cooled. The intended response includes collagen contraction and subsequent remodeling—not simply warming the outside of the face. [1] [7]

How Thermage works: surface cooling, radiofrequency heating, and collagen remodeling

In practical terms, I consider it for skin laxity, fine lines and a softer-looking facial outline. A deep fold caused mainly by volume loss or skeletal support needs a different assessment. Thermage is neither a filler nor a dedicated fat-dissolving treatment.

Thermage FLX system and treatment tips, official Solta Medical product photograph

Thermage FLX system and tips. Product photograph: Solta Medical / Thermage.

A small randomized split-face study compared Thermage FLX with a water-cooled monopolar RF system in 22 women. Both sides improved over eight weeks; the water-cooled side was less painful. The size and follow-up of that study limit broader conclusions about which device is “best.” [3]

2. Worried about hollow cheeks? These are the three areas I assess

Facial fat sits in separate compartments, divided by connective tissue and related to retaining ligaments. A fuller area beside a groove and a hollow beside that fullness can have different causes. This anatomical distinction matters more than treating every visible line. [2]

Three facial regions: 1 nasolabial fat compartment, 2 superior and inferior jowl compartments, 3 inferior orbital fat compartment

The numbered regions correspond to ①–③ below. These are superficial regions; the deep buccal fat pad, SOOF and orbital fat are different structures.

① Fullness above the nasolabial fold

The nasolabial fat compartment lies above and beside the line running from the nose toward the mouth. Descent of this tissue can make the fold look deeper—but cheek volume loss and reduced structural support can also contribute.

I look for tissue that has descended and gathered above the fold. When that pattern of laxity is the main issue, I concentrate treatment over the lax region above the fold, rather than simply tracing the crease. If the anterior cheek is already hollow, preserving volume takes priority.

② Heaviness beside the mouth and above the jawline

The superior and inferior jowl compartments are superficial fat regions near the lower cheek and jaw. When tissue gathers here, the jawline can look blurred or develop a small bulge.

I assess where the heaviness is greatest, then give that lax region more attention while sparing an already hollow lateral cheek. This is the area often loosely called “deep cheek” in Korean aesthetic discussions; it should not be confused with the deeper buccal fat pad.

③ Fullness above an under-eye groove

The inferior orbital—or infraorbital—fat compartment shown here is superficial. Under-eye fullness can also come from deeper orbital fat, and a tear-trough hollow may reflect volume loss or ligament attachment. These are not interchangeable problems.

I first separate loose skin over the fullness from the hollow below it. I also avoid concentrating excessive heat directly over an already tethered tear-trough groove, where a hollow may become more conspicuous. This is a clinical planning precaution; a claim that RF selectively tightens the tear-trough ligament and thereby deepens the groove has not been established.

Thermage 0.25 square centimeter Eye Tip, official Solta Medical product photograph

The 0.25 cm² Eye Tip is designed for shallow periorbital treatment. Product photograph: Solta Medical / Thermage.

Eyelid treatment needs the appropriate tip and the eye protection specified in the device instructions. A treatment map for the cheeks is not an eyelid protocol. [7]

3. My three practical treatment priorities

① Preserve hollow cheeks; follow the actual pattern of sagging

I mark the hollow areas first, then plan treatment around the lax areas.

On a suitable face, that may resemble a mirrored L: from the anterior cheek below the eye, down toward the jowl, then along the jawline. The vertical part is not a stripe in front of the ear. An already sunken lateral cheek is outside that emphasis.

Dr. Youro's individualized treatment map from the anterior cheek to the jowl and jawline, preserving a hollow lateral cheek

The shape is a way of explaining my assessment—not a fixed template for every face. The same map or shot count can be inappropriate for someone with a different distribution of volume.

② Heat the planned area evenly, then add selective passes

RF tissue effects depend on temperature and exposure time. My approach is to build heat evenly across the intended treatment area, then allocate additional passes to the regions with greater laxity, adjusting to skin response and patient feedback.

Even heating of the planned treatment area followed by selective passes over greater laxity, with hollow areas preserved

Already hollow areas are considered from the first pass. A surface temperature reading does not directly tell us the temperature at depth, especially when the skin is actively cooled. “Keep every face above one temperature” is therefore too simplistic. [1] [7]

③ Stable contact and deliberate pulses

For Thermage, I favor a controlled stamping rhythm: establish full contact, complete the pulse, then reposition. The purpose is consistent contact and controlled delivery to the planned area.

Full contact first. Complete each pulse, then move deliberately.

Additional passes must follow the device protocol and tissue response. Other RF systems can use validated moving techniques; a Volnewmer study used both static and sliding modes. The evidence does not support a blanket statement that gliding “cannot reach deeply enough.” [7] [5]

4. Thermage, Oligio, XERF, Density or Volnewmer?

All five use RF, but the frequency, cooling, tip design and energy delivery differ. A brand comparison is useful; it does not replace an examination.

RF treatmentWhat differs
① Thermage FLX6.78 MHz monopolar RF; automatic calibration and cooling.
② Oligio6.78 MHz monopolar RF; impedance monitoring and cooling.
③ XERFCombines 6.78 MHz and 2 MHz; treatment settings vary by region.
④ Density6.78 MHz platform; monopolar and bipolar delivery depend on the model and tip.
⑤ Volnewmer6.78 MHz monopolar RF with continuous water cooling.

Device details: Thermage, Oligio, XERF study, Jeisys Density, Classys Volnewmer. Models, tips and authorized indications vary by country.

My consultation questions stay the same: Is the concern loose skin, descended tissue, lost volume—or a combination? Which areas need treatment, and which need preservation?

5. Published RF before-and-after photos: what do they show?

The following photographs are from published studies, not my own patients. They show Oligio, Volnewmer and XERF outcomes. They are not Thermage FLX results or a head-to-head ranking. Lighting, positioning and study design matter when judging change.

Oligio: follow-up through 24 weeks

In a study of 20 women after one treatment, jowl and nasolabial laxity improved on clinical assessment. Cheek firmness also improved; measured changes in pores, fine wrinkles and skin tone were not statistically significant. There was no untreated control group. [4]

Oligio study Figure 1: representative patients before treatment and at 4, 12, and 24 weeks

Oligio, Figure 1: baseline and 4, 12 and 24 weeks. Shin et al., Cosmetics (2024), doi:10.3390/cosmetics11030071. Reproduced unchanged under CC BY 4.0.

Volnewmer: frontal and oblique views over eight weeks

A single-arm study followed 22 women after one treatment. It reported improvement in jawline measurements and changes in facial surface volume. These 3D surface measurements do not by themselves prove that fat was created or removed. [5]

Volnewmer study Figure 1: oblique clinical photographs at baseline and 2, 4, and 8 weeks

Volnewmer, Figure 1: oblique views at baseline and 2, 4 and 8 weeks. Roh et al., International Journal of Molecular Sciences (2026), doi:10.3390/ijms27125162. Reproduced unchanged under CC BY 4.0.

Volnewmer study Figure 2: frontal clinical photographs at baseline and 2, 4, and 8 weeks

Volnewmer, Figure 2: frontal views at baseline and 2, 4 and 8 weeks. Roh et al. (2026), same study. Reproduced unchanged under CC BY 4.0.

XERF: two treatments, with 90-day follow-up

A prospective study treated 39 participants twice, four weeks apart. Investigators rated 36 of 39 as improved at 90 days after the final treatment. It was an uncontrolled, unblinded study with manufacturer funding, so the findings are encouraging rather than definitive. [6]

XERF study Figure 2: a 42-year-old participant at baseline and 30 and 90 days after the final treatment

XERF, Figure 2: a 42-year-old participant at baseline, 30 days and 90 days after the final treatment. Weiss et al., Cureus (2026), doi:10.7759/cureus.104546. Reproduced unchanged under CC BY 4.0.

XERF study Figure 3: a 60-year-old participant at baseline and 30 and 90 days after the final treatment

XERF, Figure 3: a 60-year-old participant at the same time points. Weiss et al. (2026), same study. Reproduced unchanged under CC BY 4.0.

These examples show the scale and timing of changes reported in selected patients. They cannot predict your result, and they do not demonstrate that one brand is superior to the others.

6. Common questions about Thermage in Korea

When will I see results?

Change develops gradually. The manufacturer describes continued improvement over two to six months, with individual variation. I would not judge the final result from a same-day selfie. Thermage patient information

Can Thermage cause cheek hollowing?

Unwanted contour changes are a recognized concern, and an existing hollow can be mistaken for a problem that needs tightening. My planning emphasizes the difference between volume loss and laxity. That approach does not make the risk zero; unusual pain or a new contour change warrants review.

Does under-eye Thermage remove eye bags?

Loose eyelid skin and deeper protruding orbital fat are different issues. RF may be considered for appropriate skin concerns, but it does not replace an assessment of the fat, ligament attachments and hollow beneath the bag.

What about downtime and safety?

Redness and swelling can occur. Burns, altered sensation and surface irregularities are possible adverse effects. Tell the clinician about implanted electrical devices, prior procedures and relevant medical conditions before treatment. Manufacturer safety information [7]

What should I ask before booking in Korea?

Ask which device and tip will be used, what the quoted treatment area includes, who performs the procedure, and how follow-up works after you return home. Request a consultation in a language you understand. A larger shot count alone does not establish a better plan.

The best starting point is a face-specific plan: what to tighten, what to preserve, and what RF cannot correct.

If you are comparing energy-based treatments, also read my guide to ONDA lifting, treatment depth and cheek hollowing.

Your own,
Dr. Youro

Adapted and updated for English-speaking readers from my Korean article on Naver. The treatment preferences described here reflect my clinical approach; they are not a universal protocol.

References

[1] Zelickson BD, Kist D, Bernstein E, et al. Histological and ultrastructural evaluation of the effects of a radiofrequency-based nonablative dermal remodeling device: a pilot study. Archives of Dermatology. 2004;140(2):204–209. doi:10.1001/archderm.140.2.204.

[2] Wan D, Amirlak B, Rohrich R, Davis K. The clinical importance of the fat compartments in midfacial aging. Plastic and Reconstructive Surgery – Global Open. 2014;1(9):e92. doi:10.1097/GOX.0000000000000035.

[3] Roh H, Lee YI, Lee SG, Hwang JK, Jung J, Lee JH. Comparative Analysis on the Efficacy of Monopolar Radiofrequency With Continuous Water Cooling and Conventional Cryogen Spray Cooling in Facial Rejuvenation. Annals of Dermatology. 2025;37(6):397–407. doi:10.5021/ad.25.166.

[4] Shin J, Sung Y, Jin S, et al. Efficacy and Safety of Monopolar Radiofrequency for Tightening the Skin of Aged Faces. Cosmetics. 2024;11(3):71. doi:10.3390/cosmetics11030071.

[5] Roh H, Lee YI, Jung J, et al. Innovative Facial Contouring Using a Monopolar Radiofrequency Device with Continuous Water Cooling: An Integrated Clinical and Preclinical Study. International Journal of Molecular Sciences. 2026;27(12):5162. doi:10.3390/ijms27125162.

[6] Weiss RA, Wang J, DiBernardo B, Bhatia AC. Clinical Outcomes Following Dual-Frequency Noninvasive Monopolar Radiofrequency Treatment for Facial Laxity and Lower Face Lifting: A Prospective Multicenter Study. Cureus. 2026;18(3):e104546. doi:10.7759/cureus.104546.

[7] Solta Medical. Thermage FLX User Manual, P009418-05B; manufacturer instructions. Product photographs and tip information: Thermage professional website.

Leave a Reply